validation or Qualification concepts 2023

Validation or Qualification concepts In the pharmaceutical industry, the concept of qualification refers to a systematic process used to ensure that equipment, facilities, utilities, and systems are suitable for their intended purposes and operate effectively and reliably. Qualification is a critical component of Good Manufacturing Practice (GMP) and is required to meet regulatory standards, such … Read more

FDA 483 WARNING LETTER 2023

FDA 483 WARNING LETTER : A Form FDA 483, officially titled “Notice of Inspectional Observations,” is a document used by the U.S. Food and Drug Administration (FDA) during inspections of regulated facilities. The purpose of this form is to communicate to the inspected entity, typically a pharmaceutical, biotechnology, or food manufacturing facility, any observed deviations … Read more

DATA INTEGRITY 2023

DATA INTEGRITY:-

Data integrity is a critical aspect of the pharmaceutical industry, ensuring that data generated, recorded, and reported is accurate, complete, and reliable. Maintaining data integrity is essential for meeting regulatory requirements, ensuring patient safety, and upholding the credibility of pharmaceutical products. Here are key considerations and measures related to data integrity in the pharmaceutical sector:

  1. Regulatory Requirements:
    • Regulatory bodies, such as the U.S. Food and Drug Administration (FDA) and the European Medicines Agency (EMA), have specific guidelines and regulations concerning data integrity in the pharmaceutical industry. Companies must comply with these regulations to obtain and maintain approvals for their products.
  2. Good Documentation Practices (GDP):
    • Implementing good documentation practices is crucial for ensuring data integrity. This includes accurate and detailed recording of data, as well as the use of controlled and standardized documentation processes.
  3. Data Lifecycle Management:
    • Pharmaceutical companies need to manage the entire data lifecycle, from generation to archival. This involves defining processes for data creation, review, modification, storage, retrieval, and disposal. A well-defined and controlled data lifecycle helps prevent data manipulation and ensures traceability.
  4. Electronic Data Integrity:
    • With the increasing use of electronic systems, maintaining the integrity of electronic data is vital. Companies should implement secure and validated electronic data management systems that include features such as audit trails, user access controls, and data encryption.
  5. Training and Awareness:
    • Employees involved in data generation and management should receive proper training on data integrity principles and practices. Awareness programs help instill a culture of data integrity within the organization.
  6. Data Security:
    • Robust cybersecurity measures are essential to protect data from unauthorized access, tampering, or loss. This includes implementing firewalls, encryption, access controls, and regular security audits.
  7. Audit Trails and Version Control:
    • Implementing audit trails allows tracking of changes made to data, providing transparency and accountability. Version control ensures that only the most recent and authorized versions of documents are used.
  8. Quality Risk Management:
    • Employing quality risk management principles helps identify and mitigate potential risks to data integrity. This involves assessing processes, systems, and potential vulnerabilities to prevent or detect issues that could compromise data quality.
  9. Supplier and Vendor Oversight:
    • When outsourcing certain processes or relying on external suppliers, pharmaceutical companies should establish robust agreements and oversight mechanisms to ensure data integrity throughout the supply chain.
  10. Documentation Review and Approval:
    • Establishing clear procedures for the review and approval of documentation is essential. This ensures that data is reviewed by authorized personnel for accuracy and completeness before it is considered final.
  11. Continuous Improvement:
    • Implementing a culture of continuous improvement allows organizations to adapt to evolving technologies and regulatory requirements. Regularly reviewing and updating data integrity practices ensures ongoing compliance and effectiveness.
Data Integrity 2023
Data Integrity

A. Introduction

  1. In recent years, the number of observations made regarding the integrity of
    data, documentation and record management practices during inspections of following GxP

      1. good manufacturing practice (GMP) (2),
      2. good clinical practice (GCP),
        good laboratory practice (GLP) and
      3. Good Trade and Distribution Practices
        (GTDP) have been increasing.
  2. The possible causes for this may include
      • Reliance on inadequate human practices;
      • Poorly defined procedures;
      • Resource constraints;
      • The use of computerized systems that are not capable of meeting regulatory requirements or are inappropriately managed and validated.
      • Inappropriate and inadequate control of data flow;
      • Failure to adequately review and manage original data
        and records.
  3. Data governance and related measures should be part of a quality system,
    and are important to ensure the reliability of data and records in good
    practice (GxP) activities and regulatory submissions.
  4. “ALCOA+”
    • The data and records should be ‘attributable, legible, contemporaneous, original’ and accurate,
      complete, consistent, enduring, and available; commonly referred to as
      “ALCOA+”.

B. Diffination & synoms

Some definitions given below apply to the terms used in these guidelines. They
may have different meanings in other contexts.

    • ALCOA+. A commonly used acronym for “attributable, legible, contemporaneous,
      original and accurate” which puts additional emphasis on the attributes of being
      complete, consistent, enduring and available throughout the data life cycle for
      the defined retention period.
    • Archiving. Archiving is the process of long-term storage and protection of
      records from the possibility of deterioration, and being altered or deleted,
      throughout the required retention period. Archived records should include
      the complete data, for example, paper records, electronic records including
      associated metadata such as audit trails and electronic signatures. Within a GLP
      context, the archived records should be under the control of independent data
      management personnel throughout the required retention period.
    • Audit trail. The audit trail is a form of metadata containing information
      associated with actions that relate to the creation, modification or deletion of
      GxP records. An audit trail provides for a secure recording of life cycle details
      such as creation, additions, deletions or alterations of information in a record,
      either paper or electronic, without obscuring or overwriting the original record.
      An audit trail facilitates the reconstruction of the history of such events relating
      to the record regardless of its medium, including the “who, what, when and
      why” of the action.
    • Backup. The copying of live electronic data, at defined intervals, in a secure
      manner to ensure that the data are available for restoration.
      Certified true copy or true copy. A copy (irrespective of the type of media
      used) of the original record that has been verified (i.e. by a dated signature or by
      generation through a validated process) to have the same information, including
      data that describe the context, content, and structure, as the original.
      Data. All original records and true copies of original records, including source
      data and metadata, and all subsequent transformations and reports of these
      data which are generated or recorded at the time of the GMP activity and whichallow full and complete reconstruction and evaluation of the GMP activity. Data
      should be accurately recorded by permanent means at the time of the activity.
      Data may be contained in paper records (such as worksheets and logbooks),
      electronic records and audit trails, photographs, microfilm or microfiche, audio
      or video files or any other media whereby information related to GMP activities
      is recorded.
    • Data criticality. This is defined by the importance of the data for the quality and
      safety of the product and how important data are for a quality decision within
      production or quality control.
    • Data governance. The sum total of arrangements which provide assurance of
      data quality. These arrangements ensure that data, irrespective of the process,
      format or technology in which it is generated, recorded, processed, retained,
      retrieved and used will ensure an attributable, legible, contemporaneous, original,
      accurate, complete, consistent, enduring and available record throughout the
      data life cycle.
    • Data integrity risk assessment (DIRA). The process to map out procedures,
      systems and other components that generate or obtain data; to identify and
      assess risks and implement appropriate controls to prevent or minimize lapses
      in the integrity of the data.
    • Data life cycle. All phases of the process by which data are created, recorded,
      processed, reviewed, analysed and reported, transferred, stored and retrieved and
      monitored, until retirement and disposal. There should be a planned approach
      to assessing, monitoring and managing the data and the risks to those data, in
      a manner commensurate with the potential impact on patient safety, product
      quality and/or the reliability of the decisions made throughout all phases of the
      data life cycle.
    • Dynamic data. Dynamic formats, such as electronic records, allow an interactive
      relationship between the user and the record content. For example, electronic
      records in database formats allow the user to track, trend and query data;
      chromatography records maintained as electronic records allow the user or
      reviewer (with appropriate access permissions) to reprocess the data and expand
      the baseline to view the integration more clearly.
    • Electronic signatures. A signature in digital form (bio-metric or non-biometric)
      that represents the signatory. In legal terms, it is the equivalent of the handwritten
      signature of the signatory.
    • Good practices (GxP). An acronym for the group of good practice guides governing the preclinical, clinical, manufacturing, testing, storage, distribution and post-market activities for regulated pharmaceuticals, biologicals and medical devices, such as GLP, GCP, GMP, good pharmacovigilance practices (GVP) and good distribution practices (GDP).
    • Hybrid system. The use of a combination of electronic systems and paper systems.
    • Medical product. A term that includes medicines, vaccines, diagnostics and medical devices.
    • Metadata. Metadata are data that provide the contextual information required to understand other data. These include structural and descriptive metadata, which describe the structure, data elements, interrelationships and other characteristics of data. They also permit data to be attributable to an individual. Metadata that are necessary to evaluate the meaning of data should be securely linked to the data and subject to adequate review. For example, in the measurement of weight, the number 8 is meaningless without metadata, such as, the unit, milligram, gram, kilogram, and so on. Other examples of metadata include the time or date stamp of an activity, the operator identification (ID) of the person who performed an activity, the instrument ID used, processing parameters, sequence files, audit trails and other data required to understand data and reconstruct activities.
    • Raw data. The original record (data) which can be described as the firstcapture of information, whether recorded on paper or electronically. Raw data is synonymous with source data.
    • Static data. A static record format, such as a paper or electronic record, that is fixed and allows little or no interaction between the user and the record content. For example, once printed or converted to static electronic format chromatography records lose the capability of being reprocessed or enabling more detailed viewing of baseline.

Good Documentation Practices

 

Data Integrity 2023
Data Integrity

To be continued………………………………

pingback:-Data deviation in microbiology

Read more:-Laboratory incident

Read more

Compressed Air Monitoring Challenge 2023

Compressed Air Monitoring Challenge Compressed Air  Compressed air refers to the air that is compressed and stored in a container or tank under pressure. It is used in a wide range of industrial applications, such as powering pneumatic tools and machinery, providing control and actuation for automation systems, and even in medical equipment. Compressed air … Read more

Amazing GLP in Microbiology 2023

(Good Laboratory Practices)GLP in Microbiology Laboratory:GLP in Microbiology

INTRODUCTION :

Good laboratories Practices in a microbiology laboratory consist of activities that depend on several principles; aseptic technique, control of media, control of test strains, control of equipment, diligent recording and evaluation of data, and training of the laboratory staff Because of the known variability in microbiology data, reliability and reproducibility are dependent on the use of accepted methods and adherence to good laboratory practices.

Definition:

  • Aseptic technique: Aseptic technique refers to the procedure used to avoid the introduction of pathogenic organisms into the vulnerable site. The prinicple aim of an aseptic technique is to protect the patient from contamination by pathogenic organisms.
  • Seed Lot Technique: Seed Lot technique is used to provide a method for generation of a working culture no more than 5 passages removed from the original stock from the national repository.To provide a method for generation of a pure culture for laboratory work.To provide a method for generation of a traceable culture for laboratory investigations.
  • SAL-Sterility Assurance Level: Sterility assurance level (SAL) is a term used in microbiology to describe the probability of a single unit being non-sterile after it has been subjected to the sterilization process. SAL also describes the killing of efficacy of a sterilization process. A very effective sterilization process has a very low SAL.
  • Alert Level/Limit: Indicates when a process might have drifted from normal operating conditions. An investigation may be performed and corrective action may be implemented, but no action is required. It can be assumed that repetitive excursions above the alert level may be addressed as if it were an action level.
  • Action Level/Limit: Indicates that a process has drifted from normal operating conditions. An investigation must be performed and corrective action must be implemented.
  • Reference strains: Microorganisms defined at least to the genus and species level, catalogue and described according to its characteristics and preferably stating its origin. Normally obtained from a recognized national or international collection.
  • Working culture: A primary subculture from a reference stock used as a reference in Microbiological analysis.
  • Biological Safety Cabinet (BSC) : A ventilated cabinet with unidirectional HEFA- Filtered airflow and HEPA-Filtered exhaust to protect the worker from hazardous drugs. A BSC used to perform an activity must be capable of providing an ISO Class 5 environment for activity.
  • Laminar airflow system (LAF) : A device or zone within a buffer area that provides an ISO Class 5 or better environment for sterile compounding/activities. The system provides a unidirectional HEFA-filtered airflow.
  1. OBJECTIVE:

To provide a guideline for the Best Practices to be followed in a Microbiology Lab

  1. SCOPE:

The procedure is applicable to all personnel working in Microbiology Lab.

  1. RESPONSIBILITY:

  • Microbiologists/Personnel Working in Microbiology Lab
  • To follow the procedure while performing the Microbiological activities.
  • To train the new employees during on job training
  1. ACCOUNTABILITY :

  • Head-Microbiology
      • To ensure compliance to the procedures
      • To ensure all the personnel are trained and adhere to the procedures
  1. PROCEDURE: 

  • Media Preparation and Quality Control

Good Laboratory Practices

      • Culture media are the basis for most of the microbiological tests, thus safeguarding the quality of media used is the critical for the execution of all the activities. Media preparation, storage and quality control testing can assure a consistent supply of high quality media.
      • The correct composition of media if media is prepared from various ingredients should be followed. The instructions provided by the manufacturer should be followed properly if the dehydrated media or ready prepared media are used.
      • Instructions provided like addition of additives, heating/sterilization, pH adjustment etc. should be followed meticulously in order to provide a consistent quality of media from a pack/batch/lot.
      • A certificate of analysis from the Manufacturer of media with details of Batch/Lot No., Expiry date, Quality control testing details etc. should be maintained for each type/Batch/Lot of media/Ready to use /Ready to prepare media.
      • Media should be stored under appropriate conditions e.g. Cool, dry, dark. All containers esp. of dehydrated media should be tightly closed and if the media are caked or cracked or show a change in the color then the media should not be used for testing purposes and should be discarded.
      • Water of preparation of media should be free of any bactericidal, inhibitory or interfering substance and should be of a suitable microbiological quality. Preferably purified water should be used for the media preparation, but in some cases deionized or distilled water can be used. The quantity of water used for media preparation shall be recorded.
      • A calibrated balance with appropriate weight range shall be used for weighing of the media and additives used.
      • Clean weighing containers,materials and tools (eg. Spatula) should be used for media weighing and dispensing. Care should be taken to avoid any foreign contamination during weighing and dispensing. The media weights/component weights should be appropriately recorded.
      • Dehydrated media should be properly dissolved prior to dispensing in various containers, may be be heating. Care should be taken to avoid overheating as all culture media to a greater or lesser extent are heat sensitive.
      • Equipment (Water bath/Steam Pot) used for dissolution/preparation should be appropriate to allow for controlled heating,constant agitation, or mixing of media.
      • Darkening of media (Maillard-type reaction or non enzymatic browning) is a general indication of overheating.Overheated media should not be used for Microbiological testing and should be disposed off.
      • When adding supplements to the media, care should be taken to properly mix the supplements in media prior too sterilization/usage.
      • Cleaned glassware’s only shall be used for preparation of media, ensure prior to usage that the glassware’s are free of any traces of debris, foreign matter and that the traces of detergent if used are thoroughly rinsed of using appropriate water quality.
      • Sterilization of media should be performed using validated cycles or as specified by the manufacturer. Commercially available prepared media manufacturers should provide the method used for the sterilization. Manufacturer should provide if feasible the Sterility Assurance level (SAL) obtained during sterilization using Biological Indicator.
      • Autoclaving by steam sterilization is preferred method for sterilization of media, except where boiling is recommended by manufacturer to avoid deterioration of heat labile components of media. The steam sterilization cycle should be validated to ensure proper heat distribution for selected loads and volumes and should ensure sterility and effective Growth Promotion test of media.
      • The load configuration of the autoclave will influence the rate of heating,longer cycles may be required. The sterilization cycle will be dependent on the media volume and autoclave load. Sterilization cycle time in which the autoclave is slow to come up to temperature may result in overheating of the media.
      • The pH of each batch of medium shall be confirmed after it has cooled to room temperature preferably 25ºC by aseptically withdrawing a sample for testing if required. The pH of the media should be in a range as specified by the manufacturer or as per the validated process. A flat pH probe is recommended for agar surfaces, and an immersion probe is recommended for liquids.
      • Repartition of media after sterilization should be performed under unidirectional airflow (UDAF) to minimize potential for environmental contamination. This should be considered a minimum requirement for media to be used in relation to sterile product testing. This includes the cooling of media, as container lids will need to be removed during cooling to prevent build-up of condensation.
      • Prepared media should be checked for the following parameters as applicable for the sterilized tubes/plates
          • Cracked containers or lids
          • Unequal filling of containers
          • Dehydration resulting in cracks or dimpled surfaces on solid medium
          • Excessive darkening or color change
          • Crystal formation form possible freezing
          • Excessive number of bubbles
          • Microbial contamination
          • Lot number and expiry date checked and recorded
          • Sterility of the media
  • Media Storage

Good Laboratory Practices

      • Media should be transported and stored in conditions that minimize the loss of moisture, control the temperature and provide mechanical protection to the prepared media.
      • Media prepared in house should be stored under validated conditions. Do not store agar at or below 0ºC, as freezing could damage the gel structure. Protect stored media from exposure to light and excessive temperatures.
      • Media should be labeled properly with batch/lot numbers, preparation and expiry dates and media identification as applicable. Dehydrated/ Ready Prepared Media should be stored as per the manufacturers recommendation.
      • If stored for prolonged period of time the agar plates should be placed into a sealed package or container to retard moisture loss
      • Re-melting of an original container of solid media should be performed only once to avoid media quality being compromised by overheating or potential contamination. It is recommended that re-melting be performed in a heated water bath or by using free flowing steam.
      • The use of microwave ovens and heating plates is common, but care should be taken to avoid damaging media by overheating and to avoid the potential injury to laboratory personnel from glass breakage and burns.
      • The molten agar medium should be held in a monitored water bath at a temperature of 45-50ºC for not more than 8 hours. Wiping of the exterior of the container should be done prior to usage of container under LAF for pouring into sterile containers/plates etc.
      • Disposal of used culture media as well as expired media should be done as per site specific SOP, but the media should only be discarded after proper decontamination either through sterilization or usage of chemical disinfectants.
  • Testing of media

Good Laboratory Practices

      • QC testing is essential as manufacturers of media attempt to standardize raw materials from biological sources, but must constantly deal with unavoidable differences in raw materials obtained from natural sources, and therefore lot to lot variability is observed
      • Quality control testing should be performed in laboratory on all prepared media. Tests routinely performed on in house media are pH, growth promotion and periodic stability checks to confirm the expiry dating
      • When the in house prepared media are properly prepared and sterilized as per validated methods, then each batch testing can be limited to each incoming lot of dehydrated media, unless otherwise instructed by the relevant compendial testing method
      • If the media preparation is not validated, each prepared media lot should be subjected to growth promotion testing. The test organisms used for the testing should be as per the Procedure for Media Preparation SOP
      • Expiry of the media should have supporting growth promotion testing to indicate that the performance of the media still meets acceptance criteria up to and including the expiration date. The length of shelf life of the batch of media depends upon the stability of the ingredients and formulation under specified conditions as well as the storage containers.
      • An investigation should be initiated if Growth promotion testing do not meet the acceptance criteria to identify the cause of the failure. The investigation should include the corrective action plan to prevent the recurrence of the problem. Any nonconforming lot should not be used if assignable cause or corrective action to non growth promotion is undetermined.
      • Quality control testing for some of the reagents routinely used in the labs for diagnostic purposes should be performed e.g. Gram Stain kit and oxidase test reagent/discs. Select correct quality control standard microorganisms, and perform the testing prior to unknown sample diagnostic testing as per the manufacturer’s instructions.
      • Special care should be taken with media that is used in environmental monitoring studies. Media used for environmental monitoring of critical areas should preferably be double-wrapped and terminally sterilized. If terminal sterilization is not performed, media should be subjected to pre-incubation and 100% inspection prior to use within a critical area. This will prevent extraneous contamination from being carried into controlled environments and will prevent false-positive results. A raised agar level for surface contact plates should be verified.
      • Growth promotion test shall be performed after completion of pre-incubation of media plates used for environment monitoring of critical areas if the plates are not terminally sterilized.
  • Maintenance of Microbial Cultures

Microbiology Good Laboratory Practices

      • Biological cultures can be the most delicate standards to handle because their viability and characteristics are dependent on adequate handling and storage.
      • Standardizing and handling and storage of cultures by the user laboratory should be done in a way that will minimize the opportunity for contamination or alteration of growth characteristics
      • The careful and consistent treatment of stock cultures is critically important to the consistency of microbiological test results.
      • Cultures for use in various test should be acquired from a national culture collection.
      • They can .be acquired frozen, freeze dried, on slants or in ready to use forms. Confirmation of the purity of the culture and the identity of the culture should be performed prior to its use in and testing
      • Ready to use  cultures may require confirmation of purity, identity and inoculums size.
      • This confirmation of identity for commonly used laboratory strains should ideally be done at the level of genotypic analysis (i.e., DNA fingerprinting, 16S r RNA gene sequencing, or PCR analysis using suitably validated probes). Or a suitable methods to determine the genus and the species of the organism (e.g. Biochemical Enzymatic substrate kit)
      • Preparation and resuscitation of cultures should follow the instructions of the supplier or a validated, established method. The “Seed-Lot” technique is recommended for storage of stock cultures.
      • The original sample from the national culture collection is resuscitated and grown in an appropriate medium. Aliquots of this stock culture (the first transfer or passage) are suspended in a cryoprotective medium, transferred to vials, and frozen at –30ºC or below, until use. If stored at –70ºC, or in lyophilized form, strains may be kept indefinitely.
      • The frozen stocks of cultures can be used to inoculate monthly or weekly working cultures.
      • Once opened, do not refreeze unused cell culture suspensions after culturing a working suspension. The unused portion should be discarded to minimize the risk of loss of viability and contamination of the stock.
      • The number of transfers of working control cultures should be tracked to prevent excessive sub culturing that increases the risk of phenotypic alterations.
      • One passage is defined as the transfer of organisms from a viable culture to a fresh medium with growth of the microorganisms. Any form of sub culturing is considered to be transfer/passage.
      • 1.1.14 Total number of passages shall not exceed five from the original culture.
  • Maintenance of Laboratory equipment
      • Most equipment’s (incubators, water baths and steam sterilizers) are subject to standard validation practices of incoming qualification, operational qualification and performance qualification
      • Additionally periodic calibration is required (generally annually). New equipment critical to the operation of the laboratory should be qualified according to a protocol approved by the respective Quality assurance
      • Instruments (e.g. pH meters, balances, spectrophotometers) used in a microbiology laboratory should be calibrated on a regular schedule and tested to verify performance on a routine basis. The frequency of calibration and performance verification will vary based on the type of instrument and the importance of that equipment to the generation of data in the laboratory.
      • Laboratories should have a separate autoclave for decontamination. However, in exceptional cases one autoclave may be acceptable provided that extensive precautions are taken to separate decontamination and sterilization loads, and a documented cleaning programme is in place to address both the internal and external environment of the autoclave.
      • Microbiology laboratories should carry out initial verification of volumetric equipment (automatic dispensers, dispenser/diluters, mechanical hand pipettes and disposable pipettes) and then make regular checks, as appropriate, to ensure that the equipment is performing within the required specification. Initial verification should not be necessary for glassware which has been certified to a specific tolerance.
      • Equipment should be checked for the accuracy of the delivered volume against the set volume (for several different settings in the case of variable volume instruments) and the precision of the repeat deliveries should be measured.
      • Hygrometers should be calibrated, the calibration being traceable to national or international standards.
      • When centrifuges are used in test procedures, an assessment of the rotations per minute (RPM) should be made. Where it is critical, the centrifuge should be calibrated.
  • Laboratory Layout and operations
      • Laboratory layout and design should carefully consider the requirements of good microbiological practices and laboratory safety.
      • It is essential that cross contamination of microbial cultures be minimized to the greatest extent possible and it is also important that microbiological samples be handled in an environment that makes contamination highly unlikely . Where possible segregate the activities involving live bacterial cultures from clean/aseptic activities which do not involve live bacterial cultures.
      • Areas in which environmental or sterile product samples are handled and incubated should be maintained completely free of live cultures, if possible. If complete separation of live and clean culture zones cannot be accomplished, then other barriers and aseptic practices should be employed to reduce the likelihood of accidental contamination. These barriers include protective clothing, sanitization and disinfection procedures, and biological safety cabinets designated for clean or aseptic operations only.
      • Procedures for handling spills or mishaps with live cultures should be in place, and all relevant technical personnel should be trained regarding these methods. Some samples will demonstrate microbial growth and require further laboratory analysis to identify the contaminants. When growth is detected, the sample should be taken from the clean section of the laboratory to the live culture section without undue delay.
      • Sub culturing, staining, microbial identification, or other investigational operations should be undertaken in the live culture section of the laboratory. If possible, any sample found to contain growing colonies should not be opened in the clean zone of the laboratory. Careful segregation of contaminated samples and materials will reduce false-positive results.
      • Staff engaged in sampling activities should not enter or work in the live culture handling section of a laboratory unless special precautions are taken, including wearing protective clothing and gloves, and careful sanitization of hands upon exiting. Ideally, staff assigned to sampling activities, particularly those in support of aseptic processing, should not work in the vicinity of live culture laboratory operations.
      • All microbiological samples should be handled using aseptic techniques, including those taken in support of non sterile products. If possible all microbiological samples should be taken under full aseptic conditions in specialized sampling areas.
      • It is important to consider that microbial contamination of samples, which leads to false-positive results, is always possible unless careful aseptic precautions are taken. Facilities should be designed so that raw material and excipient sampling can be done under controlled conditions, including proper gowning and sterilized sampling equipment. It may not always be possible to sample utility systems, such as water systems, under full aseptic conditions; however, it should be noted that when samples are not taken aseptically, their reliability is inevitably compromised.
      • Environmental sampling methods should require minimal aseptic handling in loading and unloading sampling instruments. Whenever possible, sampling equipment should be loaded with its microbiological recovery media in the environment that is to be sampled.
      • All testing in laboratories used for critical testing procedures, such as sterility testing of final dosage forms, bulk product,  handling of seed cultures should be performed under controlled conditions.
      • There should be separate air supply to laboratories and production areas. Separate air-handling units and other provisions, including temperature and humidity controls where required, should be in place for microbiological laboratories. The air supplied to the laboratory should be of appropriate quality and should not be a source of contamination.
      • Access to the microbiological laboratory should be restricted to authorized personnel. Personnel should be made aware of:
        • the appropriate entry and exit procedures including gowning;
        • the intended use of a particular area;
        • the restrictions imposed on working within such areas;
        • the reasons for imposing such restrictions; and
        • the appropriate containment levels.
      • Consideration should be given to designing appropriate classified areas for the operations to be performed within the microbiology laboratory.The classification should be based on the criticality of the product and the operation being carried out in the area. Sterility testing should be performed under the same class as used for sterile/aseptic manufacturing operations.
      • The sterility testing should be carried out within a Grade A unidirectional airflow protected zone or a bio safety cabinet (if warranted), which should be located within a clean room with a Grade B background. Care should be taken with the design of the facility layout and room airflow patterns, to ensure that the unidirectional airflow patterns are not disrupted.Air supplied to Grade A and B zones should be via terminal HEPA filters
      • Entry to the clean room should be via a system of airlocks and a change room where operators are required to don suitable clean-room garments. The final change room should be under “at rest” conditions of the same grade as the room it serves. Change rooms should be of adequate size for ease of changing. There should be clear demarcation of the different zones.
  • Training of personnel

Speaker at Presentation/training. personnel in Trraining Hall.

      • Each person engaged in all phases of pharmaceutical microbiology operations should have the education, training and experience to do his or her job.
      • The demands of microbiological testing require that the core educational background of the staff , supervisors and managers be in microbiology or a closely related biological science.
      • They should be assigned responsibilities in keeping with their level of skill and experience.
      • A coherent system of operating procedures is necessary to run the microbiology laboratory. These procedures serve two purpose in a training program.
      • Firstly, these SOPs describe the methodology that the microbiologist will follow to obtain accurate and reproducible results, and so serve as the basis for training.
      • Secondly, by tracking the procedures in which a particular microbiologist has demonstrated proficiency, the procedure number or title also serves to identify what training the microbiologist has received specific to his or her job function.
      • Training curricula should be established for each laboratory staff member specific for his or her job function. They should not independently conduct a microbial test until they are qualified to run the test.
      • Training records should be current, documenting the microbiologists training in the proper revision to the particular SOP.
      • Periodic performance assessment  of each analyst is required to ensure data quality. This performance testing should provide evidence of competency in the core activities of the microbiology laboratory such as hygiene, plating, aseptic technique, documentation and others as suggested by the microbiologists job function.
      • Microbiologists with supervisory or managerial responsibilities should have appropriate education, experience and in house training in supervisory skills, laboratory safety, scheduling, laboratory investigations, technical report writing, relevant SOPs and other critical aspects of the company’s processes as suggested in their role of directing a laboratory function.
      • Operators should be trained and certified in gowning procedures with training records maintained.
      • Microbiological sampling ,Sample handling and transportation
      • Any disinfection processes used in obtaining the sample (e.g.disinfection of sample points) should not compromise the microbial level within the sample.
      • Transport and storage of samples should be under conditions that maintain the integrity of the sample (e.g. chilled or frozen where appropriate). Testing of the samples should be performed as soon as possible after sampling. For samples where a growth in the microbial population during transport and storage is possible it should be demonstrated that the storage conditions, time and temperature, will not affect the accuracy of the testing result. The storage conditions should be monitored and records kept. The responsibility for transport, storage between sampling and arrival at the testing laboratory should be clearly documented.
      • Sampling should only be performed by trained personnel. It should be carried out aseptically using sterile equipment. Appropriate precautions should be taken to ensure that sample integrity is maintained through the use of sterile sealed containers for the collection of samples where appropriate. It may be necessary to monitor environmental conditions, for example, air contamination and temperature, at the sampling site. Time of sampling should be recorded, if appropriate.
      • The laboratory should have procedures that cover the delivery and receipt of samples and sample identification. If there is insufficient sample or the sample is in poor condition due to physical deterioration, incorrect temperature, torn packaging or       deficient labeling, the laboratory should consult before deciding whether to test or refuse the sample.
      • Samples awaiting testing should be stored under suitable conditions to minimize changes to any microbial population present. Storage conditions should be validated, defined and recorded.
      • The packaging and labels of samples may be highly contaminated and should be handled and stored with care so as to avoid any spread of contamination. Disinfection processes applied to the outer container should not affect the integrity of the sample.
      • Laboratory sample portions that are known to be contaminated should be decontaminated prior to being discarded
  • Documentation
      • Documentation should be sufficient to demonstrate that the testing was performed in a laboratory and by methods that were under control. This includes, but not limited to documentation for the following.
          • Microbiologist training and verification of proficiency
          • Equipment validation, calibration and maintenance
          • Equipment performance during test
          • Media preparation and its growth promotion capabilities
          • Media inventory and control testing
          • Data and calculation verification
          • Reports reviewed by reviewer
          • Investigation of Microbial Data Deviations (if required)
      • If the result of the enumeration is negative, it should be reported as “not detected for a defined unit” or “less than the detection limit for a defined unit”. The result should not be given as “zero for a defined unit” unless it is a regulatory requirement. Qualitative test results should be reported as “detected/not detected in a defined quantity or volume”. They may also be expressed as “less than a specified number of organisms for a defined unit” where the specified number of organisms exceeds the detection limit of the method and this is acceptable. In the raw data the result should not be given as zero for a defined unit unless it is a regulatory requirement. A reported value of “0” may be used for data entry and calculations or trend analysis in electronic databases
  • Maintenance of Laboratory Records
      • Proper recording of data and studies is critical to the success of microbiology laboratory. The various tests should be performed as per the SOP and the laboratory notebook should provide a record of all critical details needed to confirm the integrity of the data. At a minimum, the laboratory Test Raw Data sheet should include the following:
        • Date
        • Material tested
        • Microbiologist’s name and Signature
        • Procedure number
        • Document test results
        • Deviations (if any)
        • Documented parameters (equipment used, microbial stock cultures used, media lots used etc.)
        • Management/Second review signatures
      • Every critical piece of equipment should be noted in the test data sheet an the all should be on a calibration schedule documented by SOP and maintenance records
      • Where appropriate, log books/forms should be available and supportive of the laboratory logbook records. Equipment temperatures (incubators, autoclaves) should be recorded and traceable.
      • The details of the SOP governing the test should be clearly noted in the test data sheet and changes in the data should be crossed off with a single line and initialed. Original data should not be erased or covered by any means
      • Test results should include the original plate counts, allowing a reviewer to recalculate the derived final results. Methods for data analysis should be detailed in site specific SOP’s.
  • Interpretation of Assay Results
      • Analytical microbiological assay results can be difficult to interpret for several important reasons:
      • Microorganisms are ubiquitous in nature and common environmental contaminants, particularly organisms associated with humans predominate in many types of microbiological analysis.
      • The analyst has the potential to introduce contaminating organisms during sample handling or processing in the laboratory
      • Microorganism may not be homogeneously distributed within a sample or an environment.
      • Microbiological assays are subject to considerable variability of outcome. Therefore , minor differences from an expected outcome may not be significant. Due to the variability in assays, utmost care should be taken to avoid exogenous contamination.
      • Results must be interpreted from a broad microbiological perspective considering not only the nature of the contaminant, but the likelihood of that organisms surviving in the pharmaceutical ingredient, excipient and/or environment under test. In addition, the growth characteristics of the microorganisms should be considered.
      • When result are observed that do not conform to a compendial monograph or another established quantitative target, an investigation into the finding is required.
      • There are generally two distinct reasons for the observation of microbial contamination that does not comply with a target or requirement: There may be either a laboratory error or laboratory environmental conditions that produced an invalid result, or the product contains a level of contamination or specific types of contaminants outside established levels or limits.
      • A full and comprehensive evaluation of the situation surrounding the result should be undertaken. All microbiological conditions or factors that could bring about the observed condition should be fully considered, including the magnitude of the excursion compared to established limits or levels. It is critical to know if the finding is statistically significant in light of assay variability.
      • The laboratory environment, the protective conditions in place for sampling, historical findings concerning the material under test, and the nature of the material, particularly with regard to microbial survival or proliferation in contact with the material, should be considered in the investigation.
      •  In addition, interviews with the laboratory analyst(s) may provide information regarding the actual conduct of the assay that can be valuable in determining the reliability of the result and in determining an appropriate course of action. If laboratory operations are identified as the cause of the nonconforming test outcome, then a corrective action plan should be developed to address the problem(s). Following the approval and implementation of the corrective action plan, the situation should be carefully monitored and the adequacy of the corrective action determined.
      •  If assay results are invalidated based upon the discovery of an attributable error, this action must be documented. Laboratories also should have approved procedures for confirmatory testing (retesting), and if necessary, re-sampling where specific regulatory or compendial guidance do not govern the conduct of an assay investigation.
  • Environment Monitoring of Testing areas
      • Environmental microbiological monitoring should reflect the facility used (room or UAF/LAF/BSC) and include a combination of air and surface sampling methods appropriate to the facility, such as:
          • active air sampling;
          • settle (exposure) plates;
          • surface contact — replicate organism detection and counting (RODAC)
          • plates, swabs or flexible films;
          • operators glove prints (where applicable).
      • Microbial environmental monitoring of the sterility test zone should be performed during every work session under operational (dynamic) conditions.
      • There should be written specifications, including appropriate alert and action limits for microbial contamination.

Microbiology Good Laboratory Practices

 

Microbiology Good Laboratory Practices Microbiology Good Laboratory Practices

  • Validation of Test Methods.
      • Standard (pharmacopoeial) test methods are considered to be validated. However, the specific test method to be used by a specific laboratory for testing of a specific product needs to be shown to be suitable for use in recovering bacteria, yeast and mold in the presence of the specific product. The laboratory should demonstrate that the performance criteria of the standard test method can be met by the laboratory before introducing the test for routine purposes (method verification) and that the specific test method for the specific product is suitable (test method suitability including positive and negative controls).
      • Test methods not based on compendial or other recognized references should be validated before use. The validation should comprise, where appropriate, determining accuracy, precision, specificity, limit of detection,limit of quantitation, linearity and robustness. Potentially inhibitory effects from the sample should be taken into account when testing different types of sample. The results should be evaluated with appropriate statistical methods, e.g. as described in the national, regional or international pharmacopoeias.
  • Interpretation of Alert and Action limits

      • For all the monitoring activities, such as environmental monitoring activity, compressed air monitoring activity, water analysis or any other monitoring activity with defined frequency has to be established with alert and action limits.
      • Alert Limit: Microbial levels specified in the SOP , which are a specific for a given facility and are established on the basis of baseline developed under monitoring program. Alert levels are always lower than the action level, results exceeding alert level gives early warning of the potential drift from natural operating conditions they may trigger appropriate scrutiny and follow up to address the potential problem and they may not be necessary ground for definitive corrective actions.
      • Action Limit: Microbial level specified in the SOP based on the guideline values. Action level results equal to or exceeding action level, which should trigger appropriate investigation and corrective action based on the investigation.
  • Microbiology Practice in routine analysis
      • Labeling of microbiological analysis plates/tubes shall be done as per Procedure For Labeling Of Dispensed Microbiological Media Containers
      • MET &TSM analysis plates shall be labeled at the bottom of the plates and near neck of the tubes with the media batch no., product name & batch no., stage/condition of testing if any, date of testing.
      • Environmental monitoring plates/Compressed air monitoring shall be labeled by marker pen with date of monitoring, media batch no. Room no, location no/name of location/sampling location or area at the bottom of the plate
      • Culture tubes shall be labeled with culture inoculation date, name of culture, Passage no, near the neck of the tubes.
      • Inoculums preparation plates shall be labeled by marker with date of inoculation, media batch no. Name of culture, dilution no.
      • Isolate plates shall be labeled with marker pen with the type of isolate, location name, date of monitoring, media batch no.
      • Personnel monitoring plates shall be labeled by marker with person name, date of monitoring, media batch no, monitoring location name.
      • Water analysis plates shall be labeled at the bottom of the plates and near neck of the tubes with the media batch no., sampling location ID/name, date of sampling/testing
      • Sterility analysis tubes/canisters shall be labeled near neck of the tubes/Face of the canister with the media batch no., product name & batch no., stage/condition of testing if any, date of testing.
      • To have a better traceability for the analysis plates and tubes/canisters etc. Racks/trays of incubators shall be differentiated day/date wise and all analyst/microbiologist shall incubate the plates and tubes of analysis in respective racks/trays. The differentiation can be done in trays for various activities separately.
      • On day/date of observation the plates due for release shall be removed from the incubator and the results shall be recorded in Lab data sheets and second qualified microbiologist shall verify the results recorded.
      • Note: While reading plates and tubes, if second qualified microbiologist is not available, store the plates and tubes in cold chamber for maximum of 72 hrs. Second verifier shall complete verification within 72 hrs.
      • If any differences found in results of observer and verifier, supervisor shall review and conclude the results to be reported and the supervisor shall acknowledge the same on lab data sheet.
      • The time of recording  for incubation/observation shall be noted form validated satellite clock only.
      • Only respective analyst/microbiologist responsible for plate reading shall transfer the observed plates and tubes to the decontamination area.
      • All samples which are under analysis shall be placed in designated area inside the Microbiology Lab.
      • Doors to laboratories shall not be left open.
      • Open wounds, cuts, scratches and grazes should be covered with water proof dressing.
      • Papers and reports shall be kept in separate areas away from the bio hazardous materials work area
      • Eating, drinking,smoking and storing of either food, personnel belongings or utensils in laboratory is prohibited.
      • Applying cosmetics and inserting or removing contact lenses are not permitted in the laboratory.
      • Wearing jewelry is not recommended while working under the laminar air flow hood,in sterile area and in bio safety cabinets.
      • Talking to personnel while working under the UAF/LAF/BSC is not acceptable
      • Good microbiology practices intended to avoid the release of infectious agents are to be employed.
      • Media containing anti metabolites or inhibitors shall be prepared using dedicated glassware, as carryover of these agents into the other media/samples may lead to false negatives.
      • The recommended counting range for plates inoculated with known concentration of culture is as below.
        • IF counting    Recommended countable range
        • Bacteria and Yeast on 90 mm petriplate         25-250 cfu/plate
        • Mold on 90 mm petriplate      8-80 cfu/plate
        • Bacteria,Yeast and mold on petriplate with 47 mm diameter membrane filter (used during membrane filtration technique)    20-80 cfu/filter face on a plate

6.0 ABREVIATION(S): 

UAF    : Uni directional Air Flow system

LAF    : Laminar Air Flow system

BSC    : Bio safety Cabinet

SAL    : Sterility Assurance Level

cfu       : Colony Forming units

mm      : millimeter

MET    : Microbial Enumeration test

TSM    : Test for Specified microorganisms

SOP     : Standard Operating Procedure

RODAC : Replicate Organism Detection and counting

DNA   : Deoxy ribo nucleic Acid

RNA   : Ribo nucleic Acid

PCR    : Polymerase chain reaction

HEPA : High Efficiency Particulate Air

7. ANNEXURES:

NIL

8. DISTRIBUTION:

 MB

9. REFERENCES:

NA

10. REVISION HISTORY:

New

 

Microbiologist Qualification Quality 2023

Microbiologist Qualification:-   Analyst/Microbiologist Qualification in Sterility & Bacterial Endotoxin Test: DEFINITIONS Analyst Qualification: The analyst qualification is a program that establishes, cultivate and sustain the necessary skills to provide quality data collection. OBJECTIVE To describe the procedure of Analyst Qualification For Microbiological Analysis. SCOPE This SOP shall be applicable for analyst qualification for microbiological … Read more

Operation, Cleaning & Calibration of Micropipette 2023

Operation, Cleaning & Calibration of Micropipette 2023:- A pipette (also spelt pipet) is a laboratory tool used to transport a measured volume of liquid, typically as a media dispenser, in chemistry, biology, and medicine. Pipettes are available in a variety of designs for a variety of applications, with varying degrees of accuracy and precision, ranging … Read more

Principle of Laminar Air Flow 2023

Principle of Laminar Air Flow

Operation and Cleaning of Laminar Air Flow:-

Definition:-

Laminar flow is defined as airflow in which the entire body of air within a defined space is uniform in both velocity and direction.

Principle of Laminar Air Flow

Laminar flow refers to the ability of fluid particles to move in a smooth path, with each layer moving parallel to the other. This concept has been used in the design of many aerodynamic and hydrodynamic systems to increase efficiency by reducing friction drag.

Principle of laminar air flow

  1. OBJECTIVE

  2. SCOPE

    • This SOP shall be applicable for operation and cleaning of Laminar Air Flow at Microbiology Department .
  3. RESPONSIBILITY

    • Microbiology Personnel shall be responsible for the operation and cleaning of Laminar Air Flow as per established procedure, maintaining its documents, recording observations and reporting the results.
    • Officer Microbiology or above who is trained or well versed with the procedure shall be responsible for ensuring that the same is carried out correctly and checking of documents for completeness of content.
    • Head – Microbiology/ Designee shall be responsible for the compliance of the SOP.
  4.  

    ACCOUNTABILITY

    • Microbiology – Head/ Designee shall be accountable for the proper implementation of SOP.
  5. PROCEDURE
    • Operation:
      • Connect three-pin plug of LAF with the main power supply.
      • Switch ON main power supply.
      • Switch ON the ON/OFF switch of LAF.
      • Sanitize the working surface with a disinfectant solution with 70 % v/v filtered Isopropyl alcohol
      • Switch ON ‘UV’ light at least for 15 minutes before starting the work.
      • Allow the condition to stabilize for 15 Minutes.
      • Before the start of work, switch OFF the UV light & switch ON tube light.
      • The differential pressure shall be between 7-15 mmwc. If the differential pressure observed beyond limit then inform the maintenance.
      • After completion of work, clean & sanitize the work surface with disinfectant solution with 70 % v/v isopropyl alcohol.
      • Switch OFF the tube light. Switch ON ‘UV’ light at least for 30 minutes.
      • Record the U.V. light burning status in Annexure-I. After completion of 8000 hours replace the UV Light.
      • Daily record the Magnehelic gauge observation in Annexure-I.

principle of laminar air flow

    • Cleaning:
      • Frequency of cleaning : Daily
      • Take out all the materials from LAF and place it on SS Container/ Table
      • Wipe the working surface, the side glasses and outer body of LAF with a cloth soaked in 70 % v/v isopropyl alcohol and record the cleaning details in Annexure-I.
      • Cleaning of pre-filters should be performed as per respective SOP of Engineering department
      • .
    • Requalification:
      • Requalification of LAF is done by external agency.
      • Particle count once in 1 year.
      • Air velocity in once in a year.
      • Integrity test of HEPA filters once in 1 year.
  1. ABBREVIATIONS
    • SOP :           Standard Operating Procedure
    • LAF :           Laminar Air Flow
    • UV :           Ultraviolet
    • % :           Percentage
    • v/v :           Volume By Volume
    • mm :           Millimeter
    • MB :           Microbiology
    • IPA :           Iso Propyl Alcohol
  2. REFERENCES
    • Nil
  3. ANNEXURES
    • Nil
  4. DISTRIBUTION 
    • MB

Pingback:-

 

Principle of Laminar Air Flow 2023
Environmental Monitoring 2023
Amazing GLP in Microbiology

Read more

pH Meter.

Operation, Cleaning & Calibration of pH Meter. Diffination:- The negative logarithm of Hydrogen ion concentration is called pH. The mathemetical formula is: pH Meter:– A pH metre is a device that measures hydrogen ion activity in solutions; in other words, it measures the acidity/alkalinity of a solution. The level of hydrogen ion activity is finally … Read more

Disinfectant Efficacy Test 2023

Disinfectant Efficacy test, antiseptics and other sanitizing agents. Definition:, Disinfectant: A chemical or physical agent that destroys or removes vegetative forms of harmful microorganisms when applied to surface. Antiseptic: An antiseptic is a substance which inhibits the growth, or destroys microorganisms on living tissue including skin, oral cavities and open wounds and inhibits the development … Read more